Description of 7MBR25SA120
IGBT MODULE (S series) 1200V / 25A / PIMFeatures· Low VCE(sat)
· Compact package
· P.C. board mount
· Converter diode bridge, Dynamic brake circuit
Applications· Inverter for motor drive
· AC and DC servo drive amplifier
· Uninterruptible power supply
Maximum ratings and characteristicsAbsolute maximum ratings (Tc=25°C unless without specified)
Item | Symbol | Condition | Rating | Unit |
Inverter | Collector-Emitter voltage | VCES |
| 1200 | V |
Inverter | Gate-Emitter voltage | VGES |
| ±20 | V |
Inverter | Collector current | IC | Continuous | Tc=25°C | 35 | A |
Inverter | Collector current | IC | Continuous | Tc=80°C | 25 | A |
Inverter | Collector current | ICP | 1ms | Tc=25°C | 70 | A |
Inverter | Collector current | ICP | 1ms | Tc=80°C | 50 | A |
Inverter | Collector current | -IC |
| 25 | A |
Inverter | Collector power dissipation | PC | 1 device | 180 | W |
Brake | Collector-Emitter voltage | VCES |
| 1200 | V |
Brake | Gate-Emitter voltage | VGES |
| ±20 | V |
Brake | Collector current | IC | Continuous | Tc=25°C | 25 | A |
Brake | Collector current | IC | Continuous | Tc=80°C | 15 | A |
Brake | Collector current | ICP | 1ms | Tc=25°C | 50 | A |
Brake | Collector current | ICP | 1ms | Tc=80°C | 30 | A |
Brake | Collector power dissipation | PC | 1 device | 110 | W |
Brake | Repetitive peak reverse voltage | VRRM |
| 1200 | V |
Converter | Repetitive peak reverse voltage | VRRM |
| 1600 | V |
Converter | Average output current | IO | 50Hz/60Hz sine wave | 25 | A |
Converter | Surge current (Non-Repetitive) | IFSM | Tj=150°C, 10ms half sine wave | 260 | A |
Converter | I2t (Non-Repetitive) | I2 t | Tj=150°C, 10ms half sine wave | 338 | A2s |
Operating junction temperature | Tj |
| +150 | °C |
Storage temperature | Tstg |
| -40 to +125 | °C |
Isolation voltage | between terminal and copper base *2 | Viso | AC : 1 minute | AC 2500 | V |
Isolation voltage | between thermistor and others *3 | Viso | AC : 1 minute | AC 2500 | V |
Mounting screw torque |
|
| 3.5 *1 | N·m |
*1 Recommendable value : 2.5 to 3.5 N·m (M5)
*2 All terminals should be connected together when isolation test will be done.
*3 Terminal 8 and 9 should be connected together. Terminal 1 to 7 and 10 to 24 should be connected together and shorted to copper base.